Filter Results By:

Products

Applications

Manufacturers

Voltage Sources

A precise voltage standard.

See Also: Voltage Current Sources


Showing results: 406 - 420 of 427 items found.

  • PXI-2559, 2.5 GHz, 75 Ω, Dual-Terminated SPDT PXI RF Relay Module

    778572-59 - NI

    2.5 GHz, 75 Ω, Dual-Terminated SPDT PXI RF Relay Module - The PXI‑2559 is a general-purpose switch module featuring two independently terminated single‑pole double‑throw (SPDT) relays. You can use it to add flexibility to your video switch network or to maintain uniform signal paths across multiple channels when building high-channel-count multiplexers. The PXI‑2559 termination resistors minimize reflections on open channels and protect your source or device under test from damage. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

  • Electrical Safety Test Equipment

    IBEKO Power AB

    Making a product “safe” requires an understanding of “hazards” that exist in each electrical product. Electrical shock is one of the four fundamental hazards. Because of that, it must be a part of any product electrical safety evaluation. Even though a product requires an electrical power source and uses electrical or electronic components, it should not present an electrical shock hazard to the user.Ground bond or earth continuity testing prevents electrical shock hazards. Similarly to a fault to earth, test instruments generate a high current. The standard requires that the resistance between protective earth and any conductive surface on the equipment does not exceed 0,1 Ohm. The test is performed by applying a DC current between the conductive surface and protective earth. By measuring the voltage drop, it calculates the resistance.RMO-E instruments are ideal for testing the protective bonding (grounding) of equipment following the standard IEC 61010-1. Applying current up to the value of 100 A and the ability to provide in the Contin menu (continuous operation) test current for the pre-set test duration (equal or exceeding 1 min) gives a user a possibility to easily check the protective bonding/grounding of the equipment. The full load voltage of 12 V assures proper measurement and accurate result. Finally, an instrument displays pass/fail classification according to user-preset parameters.

  • Single Channel USB Programmable Band-Pass Filter

    USBPBP-S1 - Alligator Technologies

    The USBPBP-S1 stand alone USB controllable module provides a single channel of high and low-pass filtering and high-quality instrumentation amplifier for front-end signal conditioning compatible with all popular A/D converter devices. The USBPBP-S1 is powered with 9 to 12VDC so it can be connected to a battery voltage source or the supplied 115-220VAC adapter may be used for operation with wall power anywhere in the world. When programmed from the USB port, the USBPBP-S1 will remember all of the programmed properties between power cycles. Program once and operate as a stand- alone signal conditioner without having to reprogram for every use. This is perfect for turn-key applications. It's easy to connect the USBPBP-S1 into the data collection system. Input and output signals can be routed through BNC connection or using the detachable screw terminal connectors. Optional SMA type adapters are also available.

  • Single Channel USB Programmable Instrumentation Amplifier

    USBPIA-S1 - Alligator Technologies

    The USBPIA-S1 stand alone USB controllable module provides a single channel of high-quality instrumentation amplifier and optional AC coupling, for front-end signal conditioning compatible with all popular A/D converter devices. The USBPIA-S1 is powered with 9 to 12VDC so it can be connected to a battery voltage source or the supplied 115-220VAC adapter may be used for operation with wall power anywhere in the world. When programmed from the USB port, the USBPIA-S1 will remember all of the programmed properties between power cycles. Program once and operate as a stand- alone signal conditioner without having to reprogram for every use. This is perfect for turn-key applications. It's easy to connect the USBPIA-S1 into the data collection system. Input and output signals can be routed through BNC connection or using the detachable screw terminal connectors. Optional SMA type adapters are also available.

  • Single Channel USB Programmable High-Pass Filter

    USBPHP-S1 - Alligator Technologies

    The USBPHP-S1 stand alone USB controllable module provides a single channel of high pass filtering and high-quality instrumentation amplifier for front-end signal conditioning compatible with all popular A/D converter devices. The USBPHP-S1 is powered with 9 to 12VDC so it can be connected to a battery voltage source or the supplied 115-220VAC adapter may be used for operation with wall power anywhere in the world. When programmed from the USB port, the USBPHP-S1 will remember all of the programmed properties between power cycles. Program once and operate as a stand- alone signal conditioner without having to reprogram for every use. This is perfect for turn-key applications. It's easy to connect the USBPHP-S1 into the data collection system. Input and output signals can be routed through BNC connection or using the detachable screw terminal connectors. Optional SMA type adapters are also available.

  • Manual Oscillators

    MOS-01, -01A - Compact Power Company

    The MOS-01 manual oscillator module is used as a quality, general-purpose sinewave oscillator and digital readout monitoring system in the MAC-01, -02, or -03 AC Power Sources/Frequency Converters. The unit has guaranteed operating range of 20 HZ to 20 KHZ which is covered in three one-decade scales. The LCD digital metering system is switch-selectable to readout either frequency, voltage or current. A toggle switch selects the input for the attached AC Power Source/Frequency Converter to originate from the manual oscillator itself or from an external laboratory or programmable oscillator source. With oscillator mode switch in Internal position, the BNC connector delivers the signal to drive additional slave units or for oscilloscope sync or monitoring. BNC input/output is completely isolated with 1500 VAC breakdown and excellent common mode rejection. The oscillator modules must be factory installed and calibrated.

  • Analog Sensors

    Solar Light Company Inc.

    Solar Light’s NIST-Traceable PMA-Series Analog Sensors represent the pinnacle of accuracy, durability, and selection on the market today. Our sensors measure discrete bands of the electromagnetic spectrum from the UVA, UVB, UVA+B, UVC, Visible Light, and Infrared regions. Both narrow and broad bands are available, to fit any application, including germicidal applications, environmental probes, and sensors for biologically weighted spectra (such as the erythema and CIE action spectra.) Over 135 different sensors are available in a variety of packages to fit any environment, from indoor clean rooms to harsh locations outdoors to 100 meters under water. Please note that Solar Light offers both Digital Sensors and Analog Sensors in the PMA-Series lineup. Select these Analog Sensors if you don’t need a digital display output of the reading, if you will be connecting to your own datalogger, or if you plan to use a voltage source to provide excitation voltage to the sensor and a digital volt or amp meter to read and convert the results. Analog Sensors are typically used as process sensors that are permanently installed to provide ongoing information. Typical current draw is under 1mA. (By contrast, Digital models are typically used as discrete sensors that are portable and located to provide short term information.)

  • Zero Bias Schottky Detectors

    Fairview Microwave Inc.

    Fairview Microwave’s line of coaxial packaged zero bias Schottky detectors feature matched inputs for excellent VSWR, voltage sensitivity levels that range from 100 to 500 mV/mW for small signal detection, negative video output polarity, and can withstand maximum input power levels up to +20 dBm CW. Operating temperature range covers 0°C to +90°C and storage temperature of -65°C to +125°C. These zero bias Schottky detectors utilize compact cylindrical package outlines that are made of passivated stainless steel and offer a variety of popular input/output SMA and BNC connector configurations that make them ideal for use with precision test and measurement, instrumentation, and subsystems assemblies. Numerous applications include power measurement, leveling pulsed signal sources, AM noise measurements, radar or missile guidance systems, monitoring system level performance, and pulsed RF measurements.

  • Complete Solution for Developing & Testing Discrete Voltage-Level Interfaces

    M4KDiscrete Module - Excalibur Systems, Inc.

    The M4KDiscrete module provides a complete solution for developing and testing discrete voltage-level interfaces. The M4KDiscrete contains control I/O registers that are memory-mapped and may be accessed in real time. The module supports twenty programmable I/O discretes that can record or control the external discretes that are connected to it. In addition, the module can record changes in the input discrete with an associated time tag via a built-in FIFO. Output discretes are open collector, capable of handling up to 32V with a maximum sink current of 100 mA each. Ordering Information:The user can set each discrete:• Either as input or output.• Either to TTL (0 – 5V) or Avionics (0 – 32V) voltage levels on inputs and• Either enable or disable external debounce on inputsThere is a 4092 Word FIFO (a string of 1023 discrete entries) containing the data and time tags.The M4KDiscrete module is supplied with C drivers, including source code and may be used with Exalt, Excalibur’s Analysis and Laboratory Tools, a Windows monitoring application.

  • PXI Based Multifunction Measurement and ICT Instrument

    PXI-501 - Konrad Technologies GmbH

    The PXI-501 is a multifunction measurement instrument for functional and in-circuit measurements.It combines two parametric measurement units with a digital voltmeter, a high voltage current source and a discharge unit. This powerful combination makes it the ideal instrument for classical analog in-circuit test and manufacturing defect analysis with additional functional test capabilities.With it’s fast sampling rate of up to 4MSps it speeds up measurements and is capable of measuring and generating AC signals up to 100kHz.To enhance the PXI-501 capabilities it can be combined with an ABex TM-501 or an ABex TM-404. The ABex TM-501 enhances the in and output range of the PXI-501. Furthermore, it provides a shunt current measurement upgrade. In combination with the ABex TM-404 it’s a complete in-circuit test solution with 86 channels in one ABex slot. For sure it can be upgraded to 2838 test points in one rack by simply adding additional matrix modules.With the above-mentioned terminal modules, the PXI-501 is able to act as a ABex system controller, so that no additional controller is required in the cassis.

  • Turns Ratio Testers

    TRT Advanced Series - IBEKO Power AB

    TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.

  • Precision Capacitance Meter

    TH2638C - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Precision Capacitance Meter

    TH2638 - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Precision Capacitance Meter

    TH2638B - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Precision Capacitance Meter

    TH2638A - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

Get Help